How much space to lease is the first decision, and it decides the rest. These benchmarks include desks, walkways, storage, meeting space and a share of the kitchen. They do not include common areas outside your lease.

Layout style Sq ft per person What it looks like
Dense open plan 80 to 120 Desks in pods or rows, one small meeting space
Standard mix (current typical) 130 to 150 Desks plus a meeting room and a phone booth
Private offices 165 to 250 Enclosed offices along a corridor

Sources: OfficeSpace’s 2026 summary of planning benchmarks puts most hybrid-era plans at 130 to 150 sq ft per person, against 165 to 250 before hybrid work. It also reports JLL’s 2025 benchmark moving from about 165 toward 132 sq ft per person (OfficeSpace). OSHA sets no minimum space per worker. Building codes set a separate occupant load for fire exits, which is not a planning target.

Work out how much space to lease with the office space calculator, test a space you found with the desks per square foot calculator, and read office space per employee for the full method.

A 4-person office in 360 sq ft

The plan below is a 24x15 ft room (360 sq ft, or 90 sq ft per person) for a team of four. It is in the dense range, so it works best for a team that is not all in every day.

  • Desk pod: four 60×30 in desks in two facing pairs. Each side has a 36 in chair zone, the minimum to push back and stand (UW office furniture guideline).
  • Main aisle: 48 in from the door along the end of the pod. That is wider than the 36 in accessible-route minimum, so you can walk past a pushed-back chair. It is narrower than the 59 in RoomSketcher gives for two people passing side by side, so in this plan people step aside for each other.
  • Meeting table: a 42 in round table with three chairs in the far corner. It sits 42 in from the end of the pod, the top of the 36 to 42 in range that space planners give for chairs around a small meeting table (RoomSketcher).
  • Phone booth: a single-person booth in the corner by the credenza, so calls leave the desk area.
  • Storage: a 60×18 in credenza on the bottom wall, out of the door swing.

The plan is drawn to scale in the “Featured floor plans” section below.

Desks: pods, rows or benching

Arrangement Space per desk Pros Cons
Pods of four (facing pairs) Lowest Compact, easy to share power Faces and screens in view
Rows facing a wall Medium Fewer distractions, daylight from the side Uses wall length
Benching (long shared table) Lowest Cheap and flexible Least privacy, all calls heard
Private offices Highest Quiet, private Most space and fit-out cost

Rules for any arrangement:

  • Chair zone: 36 in minimum from the desk edge, and 48 in where people walk behind a chair (UW guideline).
  • Facing desks: about 78 to 96 in center to center (Dimensions.com; RoomSketcher).
  • Desk size: 60×30 in for two monitors. 48×24 in is the minimum for a hot desk. The UW guideline recommends at least 46 in of width for computer work.
  • Screens: at right angles to windows, 20 to 40 in from the eyes (OSHA).

Meeting space and calls

In a small open office, plan for calls before meeting rooms: a meeting can be booked, but calls happen all day at the desks.

  • Phone booths or a call room: booth maker Framery’s starting ratio is one single-person booth per 6 to 12 employees, plus a meeting pod at the same ratio (as reported by Gable, 2026). Single-person booths run about $4,000 to $11,500 and multi-person pods $8,000 to $20,000 or more, against $20,000 to $30,000 for a small drywall room (same source). Check the footprint and the door swing before you buy.
  • Meeting nook: a round table for 2 to 4 needs 36 to 42 in all around it (RoomSketcher). Space planners commonly allow about 50 sq ft plus 25 sq ft per seat for a conference room (OfficeSpace).
  • Conference room: only worth its rent if it is used most days. By the 50 + 25 per seat rule, four seats need about 150 sq ft (a 10x15 ft room) and six need about 200 sq ft. A 10x12 ft room is the tight minimum for four around a 42 in round table.

Sound and privacy

Space Wall rating Source
Private office, normal privacy STC 40 minimum GSA, Sound Matters
Conference or executive room, confidential STC 45 minimum GSA, Sound Matters
Video conference or training room STC 53 minimum GSA, Sound Matters

The rating only holds if the room is sealed. The GSA guide notes that walls stopping at the ceiling, gaps around pipes and hollow-core doors let speech through whatever the wall’s rating. Run walls to the slab, seal the gaps, and fit solid doors with seals. In the open area, a rug, acoustic ceiling tiles and sound masking cut how far voices carry.

Accessibility

Businesses open to the public and employers have duties under the ADA. New construction and alterations follow the 2010 ADA Standards. The numbers that shape a layout, from the Access Board’s guide:

  • Routes: 36 in clear width (§403.5.1).
  • Doors: 32 in clear opening (§404.2.3), which in practice means a 36 in door.
  • Turning space: a 60 in circle or a T-shape (§304.3).
  • Clear floor space: 30×48 in at a desk, with knee clearance at least 27 in high and 30 in wide (§§305, 306).

Read the full list in the small office dimensions guide.

Power, data and light

  • Power: count the plugs per desk: computer, two monitors, a lamp and a charger is five. Pods need power from the floor, a power pole or a desk-mounted strip. New circuits are a job for a licensed electrician, and in a lease, for the landlord’s approval.
  • Data and Wi-Fi: put the access point high and central, not in a closet, and check its rated coverage against your floor area.
  • Light: 300 to 500 lux of general light, the IES range for offices (IES values published by LEDVANCE), with screens at right angles to windows.

The lease

  1. Usable versus rentable area. Rent is usually charged on rentable area, which includes a share of the building’s common areas. Plan your layout on the usable area. Most US landlords measure both using the BOMA office standard (ANSI/BOMA Z65.1), so ask which version your lease uses.
  2. What you can build. Walls, outlets and data cabling usually need the landlord’s written approval.
  3. Fit-out cost. Cushman & Wakefield’s 2026 guide puts the average US office fit-out at $162 per sq ft, with the big coastal markets higher (about $193 in the New York Tri-State area and $228 in San Francisco), with electrical work about 24% of the total (Cushman & Wakefield, March 2026). So a 1,000 sq ft fit-out is roughly $160,000 before furniture. Get two or three local quotes and ask what the landlord’s improvement allowance covers.
  4. Occupant load. Fire codes cap how many people a space may hold. Ask the landlord for the space’s occupant load before you sign.

Next steps

Work out your number with office space per employee, check every clearance in the small office dimensions guide, and test your floor area in the desks per square foot calculator.