How much space four people need
| Plan type | Per person | Four people | Source |
|---|---|---|---|
| Dense open plan | 80 to 120 sq ft | 320 to 480 sq ft | OfficeSpace (2026) |
| Standard mix, hybrid era | 130 to 150 sq ft | 520 to 600 sq ft | OfficeSpace |
| Private offices | 165 to 250 sq ft | 660 to 1,000 sq ft | OfficeSpace |
These figures include hallways and shared space. OfficeSpace gives circulation as 20 to 30% of usable area. Our two plans are single open rooms, so they sit at the dense end: 80 sq ft per person in the 20x16 ft room and 90 in the 24x15 ft room.
Two rules that are not planning targets: OSHA sets no minimum floor area per worker, and the building code’s occupant load (150 sq ft gross per person for business areas, IBC Table 1004.5, as reported by OfficeSpace) is for sizing fire exits. Add up your own rooms in the office space calculator, or test a space you found with the desks per square foot calculator.
2 floor plans for a 4-person office
Both plans are drawn to scale, with 60×30 in desks. The dashed outlines are chair zones and the orange dots are outlets. Use Edit in room planner under either plan to try it in your own room.
Layout A: desks on the side walls, 20x16 ft (320 sq ft)
4-person office layout: 20x16 ft (320 sq ft), desks on the side walls
20×16 ft · 320 sq ftPros
- Every desk runs at right angles to the window, as OSHA suggests for screens
- Each desk has its own wall outlet, so no cords cross the floor
- The middle of the room stays free for a 36 in round table, with 36 in on each side
- Pairs sit back to back across the room, which gives some screen privacy
Cons
- Two people sit at each long wall with their backs to the middle
- The aisles beside the table are 36 in, the minimum; chairs pushed back narrow them
Best for: A team of four in a room about 20 ft wide with windows on one short wall.
Layout B: a desk pod and a meeting table, 24x15 ft (360 sq ft)
Small business office for 4 people: 24x15 ft (360 sq ft)
24×15 ft · 360 sq ftPros
- One pod keeps the team together and frees a 48 in aisle from the door
- A 42 in round table with three chairs, 42 in from the end of the pod
- A phone booth and a credenza along the far wall
Cons
- Two people face the window and two sit with their backs to it, so add blinds
- The pod needs power at the center: a floor outlet or a power channel under the desks
Best for: A deeper room, or a team that talks across the desks all day.
Compare the two layouts
| Layout | Room | Per person | Desks | Meeting | Calls | Storage |
|---|---|---|---|---|---|---|
| A: side walls | 20x16 ft, 320 sq ft | 80 sq ft | On the walls, at right angles to the window | 36 in table, two chairs | Booth | Credenza |
| B: pod | 24x15 ft, 360 sq ft | 90 sq ft | Facing pairs in the middle | 42 in table, three chairs | Booth | Credenza |
Clearances for a 4-person office
| Clearance | Number | Source |
|---|---|---|
| Desk edge to the nearest obstacle | 36 in minimum, 48 in recommended | UW guideline |
| Accessible route | 36 in clear | ADA §403.5.1 (Access Board guide) |
| Main aisle, two people passing | about 59 in | RoomSketcher |
| Around a small meeting table | 36 to 42 in | RoomSketcher |
| Door clear width | 32 in, which in practice means a 36 in door | ADA §404.2.3 (Access Board guide) |
| Turning space | 60 in circle | ADA §304.3 (Access Board guide) |
The ADA applies to employers and to businesses open to the public, so these numbers are requirements for most small business offices, not just good practice.
Sound, power and light
- Sound: four people on calls is the first thing that goes wrong in a small office. A single-person phone booth or a small call room gives people somewhere to go. For the costs and how many booths to plan, see meeting space and calls. For a meeting room with a door, the GSA’s acoustic guide asks for STC 45 walls for confidential speech (GSA, Sound Matters).
- Power: plan one outlet location per desk before you sign the lease. Desks on the walls (Layout A) can use wall outlets. A pod (Layout B) needs a floor outlet or a power channel. New circuits are a job for a licensed electrician.
- Light: about 300 to 500 lux of general light for offices (IES values published by LEDVANCE), with screens at right angles to the windows.
Mistakes to avoid with four desks
- Rows of desks facing the window. Everyone gets glare on screen, and the person behind sees every screen in front.
- Counting the desks and forgetting the extras. Four 60×30 in desks and their chair zones take only about 110 sq ft; the table, the booth, storage and aisles take the rest.
- A pod with no power plan. Cords across the aisle are a trip hazard. Budget for a floor outlet or a desk power channel.
Two people instead of four? See the office layout for 2 people. Planning the whole office? The small business office design guide covers reception, meeting rooms and fit-out costs.