How much space four people need

Plan type Per person Four people Source
Dense open plan 80 to 120 sq ft 320 to 480 sq ft OfficeSpace (2026)
Standard mix, hybrid era 130 to 150 sq ft 520 to 600 sq ft OfficeSpace
Private offices 165 to 250 sq ft 660 to 1,000 sq ft OfficeSpace

These figures include hallways and shared space. OfficeSpace gives circulation as 20 to 30% of usable area. Our two plans are single open rooms, so they sit at the dense end: 80 sq ft per person in the 20x16 ft room and 90 in the 24x15 ft room.

Two rules that are not planning targets: OSHA sets no minimum floor area per worker, and the building code’s occupant load (150 sq ft gross per person for business areas, IBC Table 1004.5, as reported by OfficeSpace) is for sizing fire exits. Add up your own rooms in the office space calculator, or test a space you found with the desks per square foot calculator.

2 floor plans for a 4-person office

Both plans are drawn to scale, with 60×30 in desks. The dashed outlines are chair zones and the orange dots are outlets. Use Edit in room planner under either plan to try it in your own room.

Layout A: desks on the side walls, 20x16 ft (320 sq ft)

4-person office layout: 20x16 ft (320 sq ft), desks on the side walls

20×16 ft · 320 sq ft
4-person office layout: 20x16 ft (320 sq ft), desks on the side wallsA 20 by 16 foot office, 240 by 192 inches inside, which is 80 sq ft per person. A 36 inch door is on the bottom wall at the left and swings in. A 120 inch window is centered on the top wall. Two 60 by 30 inch desks stand on the left wall and two on the right wall, at right angles to the window, each with a 36 inch chair zone. A 36 inch round table with two chairs sits in the middle with 36 inches on each side. A 36 by 36 inch phone booth stands in the bottom right corner and a 60 by 18 inch credenza runs along the bottom wall.Desk30×60 inDeskDeskDeskChairChairChairChairTableChairChairBooth36×36 inCredenza60×18 in36" chair zone36" chair zone20'16'2 ft · drawn to scale
Four desks on the side walls, a small table, a phone booth and storage in 320 sq ft. Drawn to scale.Edit in room plannerDownload PDFPNGSVG

Pros

  • Every desk runs at right angles to the window, as OSHA suggests for screens
  • Each desk has its own wall outlet, so no cords cross the floor
  • The middle of the room stays free for a 36 in round table, with 36 in on each side
  • Pairs sit back to back across the room, which gives some screen privacy

Cons

  • Two people sit at each long wall with their backs to the middle
  • The aisles beside the table are 36 in, the minimum; chairs pushed back narrow them

Best for: A team of four in a room about 20 ft wide with windows on one short wall.

Layout B: a desk pod and a meeting table, 24x15 ft (360 sq ft)

Small business office for 4 people: 24x15 ft (360 sq ft)

24×15 ft · 360 sq ft
Small business office for 4 people: 24x15 ft (360 sq ft)A 24 by 15 foot office, 288 by 180 inches inside, which is 90 sq ft per person. A 36 inch door is on the bottom wall at the left and swings in. A 144 inch window runs along the top wall. Four 60 by 30 inch desks form a pod of two facing pairs, with a 36 inch chair zone on each side and a 48 inch aisle from the door along the left wall. A 42 inch round meeting table with three chairs sits in the top right, 42 inches from the end of the pod. A 36 by 36 inch phone booth stands in the bottom right corner and a 60 by 18 inch credenza runs along the bottom wall beside it.Desk60×30 inDeskDeskDeskChairChairChairChairTableChairChairChairBooth36×36 inCredenza60×18 in36" chair zone36" chair zone48" aisle24'15'2 ft · drawn to scale
Four desks, a meeting table, a phone booth and shared storage in 360 sq ft. Drawn to scale.Edit in room plannerDownload PDFPNGSVG

Pros

  • One pod keeps the team together and frees a 48 in aisle from the door
  • A 42 in round table with three chairs, 42 in from the end of the pod
  • A phone booth and a credenza along the far wall

Cons

  • Two people face the window and two sit with their backs to it, so add blinds
  • The pod needs power at the center: a floor outlet or a power channel under the desks

Best for: A deeper room, or a team that talks across the desks all day.

Compare the two layouts

Layout Room Per person Desks Meeting Calls Storage
A: side walls 20x16 ft, 320 sq ft 80 sq ft On the walls, at right angles to the window 36 in table, two chairs Booth Credenza
B: pod 24x15 ft, 360 sq ft 90 sq ft Facing pairs in the middle 42 in table, three chairs Booth Credenza

Clearances for a 4-person office

Clearance Number Source
Desk edge to the nearest obstacle 36 in minimum, 48 in recommended UW guideline
Accessible route 36 in clear ADA §403.5.1 (Access Board guide)
Main aisle, two people passing about 59 in RoomSketcher
Around a small meeting table 36 to 42 in RoomSketcher
Door clear width 32 in, which in practice means a 36 in door ADA §404.2.3 (Access Board guide)
Turning space 60 in circle ADA §304.3 (Access Board guide)

The ADA applies to employers and to businesses open to the public, so these numbers are requirements for most small business offices, not just good practice.

Sound, power and light

  • Sound: four people on calls is the first thing that goes wrong in a small office. A single-person phone booth or a small call room gives people somewhere to go. For the costs and how many booths to plan, see meeting space and calls. For a meeting room with a door, the GSA’s acoustic guide asks for STC 45 walls for confidential speech (GSA, Sound Matters).
  • Power: plan one outlet location per desk before you sign the lease. Desks on the walls (Layout A) can use wall outlets. A pod (Layout B) needs a floor outlet or a power channel. New circuits are a job for a licensed electrician.
  • Light: about 300 to 500 lux of general light for offices (IES values published by LEDVANCE), with screens at right angles to the windows.

Mistakes to avoid with four desks

  1. Rows of desks facing the window. Everyone gets glare on screen, and the person behind sees every screen in front.
  2. Counting the desks and forgetting the extras. Four 60×30 in desks and their chair zones take only about 110 sq ft; the table, the booth, storage and aisles take the rest.
  3. A pod with no power plan. Cords across the aisle are a trip hazard. Budget for a floor outlet or a desk power channel.

Two people instead of four? See the office layout for 2 people. Planning the whole office? The small business office design guide covers reception, meeting rooms and fit-out costs.